fix: pos systemd units stop fast — TimeoutStopSec=5s everywhere, listener TERM traps; drop dead pos-health/pos-entertainment unit docs

This commit is contained in:
Your Name
2026-08-13 13:16:58 +00:00
parent 8b0ce3ba89
commit d9316ec7f7
15 changed files with 82 additions and 67 deletions
+11
View File
@@ -323,6 +323,17 @@ then listing it in `NOTIFY_PLATFORM`. Platform keys map to tool names via `notif
Check before creating, use `>>` with grep guards, don't overwrite user configs.
### Systemd units
Every unit a tool writes (or `systemd/` ships) sets `TimeoutStopSec=5s` so a
stuck process can't stall a reboot for the 90s systemd default. Long-polling
daemons (listeners) also `trap TERM INT` in their loop so a stop returns in
well under a second — the unit timeout is the backstop. Keep `KillMode=`
explicit (`control-group`) on the daemons. A oneshot job running at shutdown is
SIGKILLed 5s after stop begins — fine, `Persistent` timers re-run it next boot.
Existing installs keep the old unit files until the tool rewrites them (re-run
the `enable` path), so template changes need a regeneration step on live boxes.
### Managed Config Blocks