fix: pos systemd units stop fast — TimeoutStopSec=5s everywhere, listener TERM traps; drop dead pos-health/pos-entertainment unit docs
This commit is contained in:
+11
@@ -323,6 +323,17 @@ then listing it in `NOTIFY_PLATFORM`. Platform keys map to tool names via `notif
|
||||
|
||||
Check before creating, use `>>` with grep guards, don't overwrite user configs.
|
||||
|
||||
### Systemd units
|
||||
|
||||
Every unit a tool writes (or `systemd/` ships) sets `TimeoutStopSec=5s` so a
|
||||
stuck process can't stall a reboot for the 90s systemd default. Long-polling
|
||||
daemons (listeners) also `trap TERM INT` in their loop so a stop returns in
|
||||
well under a second — the unit timeout is the backstop. Keep `KillMode=`
|
||||
explicit (`control-group`) on the daemons. A oneshot job running at shutdown is
|
||||
SIGKILLed 5s after stop begins — fine, `Persistent` timers re-run it next boot.
|
||||
Existing installs keep the old unit files until the tool rewrites them (re-run
|
||||
the `enable` path), so template changes need a regeneration step on live boxes.
|
||||
|
||||
### Managed Config Blocks
|
||||
|
||||
To let a tool own a slice of a user/system config file (e.g. Samba shares in `/etc/samba/smb.conf`) without clobbering hand edits, delimit the tool's section with start/end marker lines and rewrite only that slice:
|
||||
|
||||
Reference in New Issue